Author Archive

Liquid Chromatography – Mass Spectrometry: Start to Finish on One Microfluidic Chip

Researchers at Virginia Tech have designed a microfluidic system that integrates optimized fluid handling, liquid chromatography, and a mass spectrometry sample platform – all in one small device.

Matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) is a powerful analytical tool which enables the identification and quantification of thousands of proteins and peptides within a single complex sample. Liquid chromatography (LC) can be used to pre-sort sample contents by mass, increasing the sensitivity and selectivity of the MS measurements. A novel system designed by Iulia Lazar and Jarod Kabulski (view the full paper here) allows the entire process of LC-MS to be carried out on a microfluidic chip.

Lazar and Kabulski’s chip has several features that set it apart from previous microfluidic devices incorporating LC and MS.1 It comprises a unique microfluidic system2 driven by electro-osmotic pumps, an LC channel packed with microparticles, and a novel system of transverse microchannels to draw LC fractions from the main separation channel and into a series of reservoirs. The chip can then be directly loaded into the MALDI-MS instrument for analysis. Flow control in the LC channel was carefully optimized so that the solution components would be perfectly distributed along the channel length.

Figure: The LC-MS microfluidic chip. (Figure 2 from the original paper.)

Using the microfluidic LC-MS chip, the researchers were able to obtain results comparable to conventional LC-MS, for both peptide mixtures and cytoplasmic cell extract. Thus, the chips are very promising for practical high-throughput applications such as biomarker screening. The chip format will also enable samples to be collected and prepped by an MS non-expert at a remote location, then transported to a MS lab for analysis.

Learn more from this HOT article from Lab on a Chip!

Microfluidic LC device with orthogonal sample extraction for on-chip MALDI-MS detection
Iulia M. Lazar and Jarod L. Kabulski
DOI: 10.1039/c3lc50190f

  1. D. Gao et al., Lab on a Chip 13, 3309-3322, 2013.
  2. I. Lazar et al., Analytical Chemistry 78 (15), 5513-5524, 2006.
Digg This
Reddit This
Stumble Now!
Share on Facebook
Bookmark this on Delicious
Share on LinkedIn
Bookmark this on Technorati
Post on Twitter
Google Buzz (aka. Google Reader)

Finding a needle in a haystack

Many diseases, especially cancers (and recurrences), are not detected until it is too late for effective treatment. Often, this is because available tests lack the sensitivity to find the appropriate protein biomarker in the body.1 Consequently, ultrasensitive tools for measuring proteins are vital for early diagnosis of diseases, and monitoring the effectiveness of surgery or therapy.

For 40 years, scientists and clinicians have been using immunoassays for protein detection. This technique relies on the precise recognition of a target molecule (antigen) by a unique Y-shaped protein (antibody) among thousands of interfering species. However, to achieve ultrasensitive detection, the antigen must be effectively transported to the antibody on the detection surface.2

To tackle this problem, a research team led by Prof. Martin Gijs drew inspiration from the human immune system. In the body, white blood cells are transported to the site of injury with the help of adhesion molecules. In the presence of blood flow, weak adhesion molecules cause the cells to slow down and roll along the vessel wall. This “rolling adhesion” allows the cells to search the wall meticulously for a stop signal. If they come across this signal, the cells will adhere firmly to the wall and squeeze into the site of injury.

Taking cue from this phenomenon, the research team designed a microfluidic immunoassay using two sizes of magnetic beads coated with antibodies. First, ‘large’ (2.8 micrometer) beads are loaded with antigen (from the serum sample) in an on-chip mixing chamber. After unbound components are washed away, the large beads are flown over a surface decorated with a pattern of ‘small’ antibody-coated (1.0 micrometer) beads. In the presence of a magnet, the large beads will roll on the surface and interact closely with the small beads (via magnetic dipolar forces). Beads that are loaded with antigen will adhere firmly to the surface through antibody-antigen complexes, while beads with no antigen are washed away (via flow-induced drag forces).

The antigen concentration in the serum sample can be detected by simply counting the number of large beads in the detection area. This method can rapidly (<20 min) detect down to 200 proteins (Tumor necrosis factor-α) in a 5 microliter of sample (i.e. 60 attomolar), making it one of the fastest and most sensitive immunoassays ever reported. Such salient technique has the potential to improve treatment and outcome for cancer patients worldwide.

The above paper is part of our Lab on a Chip Top 10%, a collection of articles selected by the Editors at Lab on a Chip, from all our high quality papers, to be of exceptional significance for the miniaturisation community. Papers in this category will have received excellent reports during peer review, and demonstrate a breakthrough in device technology, methodology or demonstrate important new results for chemistry, physics, biology or bioengineering enabled by miniaturisation.

The full paper details are here: Attomolar protein detection using a magnetic bead surface coverage assay, H. Cumhur Tekin, Matteo Cornaglia and Martin A. M. Gijs*, Lab Chip, 2013, 13, 1053-1059. DOI: 10.1039/C3LC41285G

1. C. S. Thaxton, R. Elghanian, A. D. Thomas, S. I. Stoeva, J.-S. Lee, N. D. Smith, A. J. Schaeffer, H. Klocker, W. Horninger, G. Bartsch and C. A. Mirkin, Proceedings of the National Academy of Sciences, 2009, 106, 18437-18442.

2. T. M. Squires, R. J. Messinger and S. R. Manalis, Nature Biotechnology, 2008, 26, 417-426.

Digg This
Reddit This
Stumble Now!
Share on Facebook
Bookmark this on Delicious
Share on LinkedIn
Bookmark this on Technorati
Post on Twitter
Google Buzz (aka. Google Reader)

Lab-on-a-Chip: The Most Cited Articles of 2010 and 2011

Lab-on-a-Chip would like to present the most cited articles of 2010 and 2011! We would like to use this opportunity to highlight some of the excellent work that the miniaturisation community is producing right now, and to congratulate our authors on their fantastic achievements.    

As of now, all of the below articles will be free for 4 weeks (until Monday 16th Sept),* so make the most of this opportunity to download the full papers!    


 

 

   

Top 3 Cited Reviews:    

  1. CN Baroud et. al.: Dynamics of microfluidic droplets (DOI: 10.1039/c001191f).

    A critical review on the current understanding of the formation, transport and merging of drops in microfluidics. Baroud and colleagues discuss the physical ingredients that differentiate droplet microfluidics from single-phase microfluidics.



      

  2. YK Cho et. al.: Centrifugal microfluidics for biomedical applications (DOI: 10.1039/b924109d).

    A critical review on the biomedical applications of centrifugal microfluidics. Cho and colleagues review current sample-to-naswer systems and the challenges that must be faced before the centrifugal platform can be used as a new diagnostic platform.



      

  3.  GB Lee et. al.: Microfluidic cell culture systems for drug research (DOI: 10.1039/b921695b).

    A tutorial review on microfluidic cell cultures and their use in drug research. The review covers the issues of cell immobilisation, medium pumping and gradient generation, as well as providing examples of practical applications.



      

Top 10 Cited Research Papers:    

  1. GM Whitesides et. al.: Electrochemical sensing in paper-based microfluidic devices (DOI: 10.1039/b917150a).

    A paper on the fabrication and performance of microfluidic paper-based sensing devices. Whitesides and colleagues demonstrated that their paper-based electrochemical devices are capable of quantifying concentrations of various analytes, including heavy metal ions and glucose.



      

  2. D Di Carlo et. al.: Sheathless inertial cell ordering for extreme throughput flow cytometry (DOI: 10.1039/b919495a).

    A paper which demonstrates the use of a microfluidic device for flow-cytometry with extreme throughput. Di Carlo and colleagues demonstrated 86-97% cell counting sensitivity and specificity.


     


      

  3. A Ozcan et. al.: Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications (DOI: 10.1039/c000453g).

    Ozcan and colleagues demonstrate a lensless on-chip microscope weighing only approx. 46 g and dimensions smaller than 5 cm3. The microscope achieves subcellular resolution and may offer a cost-effective tool in the development of portable medicine.


      

  4. D Di Carlo et. al.: Deformability-based cell classification and enrichment using inertial microfluidics (DOI: 10.1039/c0lc00595a)


  5. BJ Kirby et. al.: Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody (DOI: 10.1039/b924420d)


  6. A Ozcan et. al.: Lensfree microscopy on a cellphone (DOI: 10.1039/c003477k)


  7. CF Carlborg et. al.: A packaged optical slot-waveguide ring resonator sensor array for multiplex label-free assays in labs-on-chips (DOI: 10.1039/b914183a)


  8. T Franke et. al.: Surface acoustic wave actuated cell sorting (SAWACS) (DOI: 10.1039/b915522h)


  9. JL Osborn et. al.: Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks (DOI: 10.1039/c004821f)


  10. LG Griffith et. al.: Perfused multiwell plate for 3D liver tissue engineering (DOI: 10.1039/b913221j)


     

*free through an RSC publishing personal account  

 

Digg This
Reddit This
Stumble Now!
Share on Facebook
Bookmark this on Delicious
Share on LinkedIn
Bookmark this on Technorati
Post on Twitter
Google Buzz (aka. Google Reader)